Published performance data

Technology

Tested battery performance from MOLECULAR REBAR® formulations in lithium-ion and lead-acid applications.

Lithium-ion electrode SEM micrograph at 20,000 times magnification with carbon nanotubes highlightedLi / Lithium-ion
Lead-acid electrode SEM micrograph at 20,000 times magnification with carbon nanotubes highlightedPb / Lead-acid
20,000× SEM imagingNanotube networks across both chemistries
01

globally Validated.

Proven in hundreds of customer products world wide.

02

Faster charging

High rate lithium ion and lead acid charging.

03

Longer battery life

More available vehicle range with lead acid and Lithium applications.

04

Process improvement

improved factory output, Safety, and economics.

Benefits in lithium-ion

Faster charging. More available vehicle range.

Molecular Rebar-based improvements to available vehicle range are observed following increasingly high rates of charge.

Limitations in charge times have been a key barrier to electric vehicle adoption globally. With Molecular Rebar, charge times can be decreased substantially over typical carbon-black-based formulations.

Impact160 miles delivered in 15 minutes.

Molecular Rebar permits high charge currents to flow for longer before becoming limited by the battery's resistance. This improvement over conventional formulations opens new doors for battery and charger design.

Original BDS graph comparing available vehicle range at increasing charge rates

Lithium-ion validation

Proven performance in large-format cells.

Our processing and formulation technology results in improved performance from any raw nanomaterial.

  • Li1330 improves performance 100% versus a competitor MWCNT product.
  • Li1365 improves performance 25% versus a competitor SWCNT product.
Original BDS graph showing Li1365 cycling performance in large-format pouch cells

Reduction in warranty claims and water loss failures.

Laboratory Testing

25% Increase in SAE J2185 w/ 10L Pb1110N (19 vs. 15wks)
Higher sustained HRD and improved active material integrity

Field Testing (12 Months data, >20,000 batteries)

Overall warranty return rate reduced by ~50%
Over-charge/water-loss field returns reduced by 70%

Original slide 21 bar graph with Y-axis header percent reduction in warranty claims and X-axis headers Total Failures and Failures Related to Water Loss

Validation in lead acid.

Increased battery life and charge acceptance.

Our impact in lead-acid battery performance goes beyond our lab. One of our new solutions graduated from our 2V Lab and was validated in an EU 12V build of excellent quality.

Side-by-side spider graphs showing initial characterization, charge acceptance, and life improvements for the MR AUX solution versus the existing OEM product

Apply the technology

What should your next battery do better?

Bring us your chemistry, format, and performance target. We’ll help identify the right formulation and validation path.

Talk to technical sales